Creators:Nau, Gerardo; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA, Albertal, Mariano; Departamento de Investigación, ICBA, Cura, Fernando; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA, Padilla, Lucio; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA, Candiello, Alfonsina; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA, Torrent, Fabricio; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA, Peralta, Sebastián; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA, Belardi, Jorge; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA

Available Downloads

See details

Archivo Size
/journals/13/articles/1489/public/1489-7102-1-PB.pdf
394.19 kB
/journals/13/articles/1489/public/1489-6903-2-PB.pdf
455.26 kB
Descripción

Introducción La angiografía convencional (AC) es la técnica de referencia para el diagnóstico de la enfermedad coronaria. Sin embargo, requiere múltiples proyecciones ortogonales para determinar el grado de enfermedad. La técnica de angiografía rotacional dual (ARD) permite una única adquisición e inyección de contraste para cada coronaria, con potencial reducción del volumen de contraste y de la dosis de radiación. Objetivo Comparar ambas técnicas (AC vs. ARD) a través de la evaluación de cantidad de contraste, exposición a la radiación y eficiencia diagnóstica. Material y métodos El presente es un estudio prospectivo, consecutivo, autocontrolado de coronariografías electivas para comparar AC y ARD. Todas las angiografías fueron revisadas por dos hemodinamistas independientes (observador 1 y observador 2) para evaluar la concordancia entre ambos tipos de imágenes. Para prevenir un sesgo en la lectura de las imágenes, los observadores evaluaron primero las ARD y tres semanas más tarde hicieron lo propio con las AC. Resultados Con la ARD se observó una reducción en la utilización de contraste (33,29 ± 11,2 ml vs. 17 ± 5,4 ml; p < 0,01) y en la exposición a radiación del paciente (235,6 ± 76,8 mGy vs. 82,7 ± 46,6 mGy; p < 0,01) y del operador (5,7 ± 3,26 mSv vs. 2,48 ± 1,47 mSv; p < 0,04). Se observó una leve diferencia y una fuerte correlación en el número de lesiones, diámetro del vaso y porcentaje de estenosis entre ambos observadores y entre ambos métodos. La evaluación categórica del porcentaje de estenosis también demostró una concordancia adecuada. Conclusión La ARD reduce el uso de contraste y la exposición a radiación en comparación con la técnica convencional, sin alterar la eficiencia diagnóstica del estudio.Rev Argent Cardiol 2012;80 doi:10.7775/rac.v80.i4.1489

Conventional coronary angiography (CA) is the gold standard for the diagnosis of coronary artery disease. However, this technique requires several orthogonal projections to determine the severity of the disease. Dual-axis rotational coronary angiography (DARCA) is a new technique which acquires the image of each coronary artery using a single contrast injection, potentially reducing both radiation and contrast exposure. Objective The aim of this study was to determine the amount of contrast used, radiation exposure and diagnostic accuracy of DARCA compared to conventional CA. Methods We conducted a prospective, self-controlled study of consecutive patients undergoing elective coronary angiography to compare DARCA versus the conventional technique. All the angiographies were reviewed by two independent interventional cardiologists (observer 1 and observer 2) who evaluated agreement between both types of images. The observers evaluated firstly DARCA and three weeks later conventional CA images to prevent bias in their interpretation. Results The contrast volume used in the diagnostic procedure was significantly lower with DARCA (33.29 ± 11.2 ml vs. 17±5.4 ml; p < 0.01). Radiation exposure in the patient (235.6 ± 76.8 mGy vs. 82.7 ± 46.6 mGy; p <0.01) and operator was also significantly lower (5.7 ± 3.26 mSv vs. 2.48 ± 1.47 mSv; p <0.04). A slight difference and a strong correlation were seen in the number of lesions, vessel diameter and percentage of stenosis between both observers and both methods. Categorical assessment of percentage of stenosis also showed adequate agreement. Conclusion DARCA reduces the use of contrast agents and radiation exposure compared to the conventional technique without modifying the diagnostic accuracy of the method.

Metadatos destacados

Colecciones
Argentine Journal of Cardiology

Editor

Sociedad Argentina de Cardiología

Fuente

Revista Argentina de Cardiología; Vol 80, No 4 (2012), Argentine Journal of Cardiology; Vol 80, No 4 (2012)

Citación

Nau, Gerardo; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA et al., “Angiografía coronaria con técnica rotacional doble: eficacia y seguridad frente a la coronariografía convencional,” Archivo PPCT, consulta 2 de abril de 2026, http://archivoppct.caicyt.gov.ar/items/show/8130.

Dublin Core

Autor

Nau, Gerardo; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA
Albertal, Mariano; Departamento de Investigación, ICBA
Cura, Fernando; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA
Padilla, Lucio; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA
Candiello, Alfonsina; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA
Torrent, Fabricio; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA
Peralta, Sebastián; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA
Belardi, Jorge; Servicio de Cardiología Intervencionista y Terapéuticas Endovasculares, ICBA

Fuente

Revista Argentina de Cardiología; Vol 80, No 4 (2012)
Argentine Journal of Cardiology; Vol 80, No 4 (2012)

Editor

Sociedad Argentina de Cardiología

Fecha

2012-07-26

Derechos

Los que firman al pié, certificamos que tenemos total responsabilidad por la conducción de este estudio y por el diseño y la interpretación de los datos. Nosotros escribimos el manuscrito y somos responsables por la decisión acerca del mismo. Cada uno de nosotros cumple la definición de autor como se afirma en el Comité Internacional de Editores de Revistas Médicas (International Committee of Medical Journal Editors, ver www.icmje.org). Nosotros hemos visto y aprobado el manuscrito final. Ni el artículo, ni ninguna parte esencial del mismo, incluido las tablas y las figuras, será publicado o admitido para arbitrar a otra parte antes de aparecer en la Revista.También notificamos haber leído la sección “conflicto de intereses”, y revelaríamos cualquiera que existiera. Dejamos constancia que si nuestro artículo se publicara en la RAC, cederíamos los derechos (copyright) a la Revista.Los documentos publicados en esta revista están bajo la licencia Creative Commons Atribución-NoComercial-Compartir-Igual 2.5 Argentina.
Those signing below certify that we have full responsibility for the conduction of this study and for the design and interpretation of the information. We wrote the manuscript and are responsible for its decision. Each of us fulfills the definition of authorship as stated by the International Committee of Medical Journal Editors ( www.icmje.org). We have signed and approved the final manuscript. Neither the manuscript, nor any essential part thereof, including tables and figures, will be published or accepted for refereeing elsewhere before being published in the Journal. We have also read the "Conflict of Interest" section and would disclose any existing. We state that if our manuscript is published in the RAC, we shall transfer the copyright to the Journal.

Idioma

spa
eng

Tipo

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion