Una imagen vale mas que mil numeros. Utilidad de un Novedoso Dispositivo para Monitoreo Hemodinamico basado en Ecocardiografia Transesofagica en Postoperatorio de Cirugia Cardiaca;
An Image is Worth a Thousand Numbers. Transesophageal Echocardiography Monitoring in Cardiac Surgery

Creators:Levin, Ricardo Luis; Vanderbilt University Medical Center, Degrange, Marcela Adriana; Universidad Abierta Interamericana, Porcile, Rafael, Salvagio, Flavio; Universidad Abierta Interamericana, Botbol, Alejandro Livio; Universidad abierta interamericana, Balaguer, jORGE Martin; Vanderbilt University, Byrne, John

Available Downloads

See details

Archivo Size
/journals/13/articles/3102/public/3102-38579-1-PB.pdf
370.53 kB
/journals/13/articles/3102/public/3102-39164-1-PB.pdf
462.87 kB
Descripción

Objetivos: Valorar el empleo de una nueva sonda miniaturizada para monitoreo hemodinámico basado en ecocardiograma transesofágico continuo analizando: número de pacientes evaluados, indicaciones de utilización, hallazgos hemodinámicos, y complicaciones asociadas. Material y Métodos: Fueron incluidos pacientes intervenidos entre el 1 de Octubre de 2010 y el 1 de Julio de 2012, empleándose el dispositivo ante inestabilidad hemodinámica. Resultados: Se utilizó el dispositivo en 252(17.6%) de 1435 cirugías. Los hallazgos principales resultaron: hipovolemia en 76(71.7%) de 106 pacientes hipotensos(sin aparente hipovolemia) así como en 27(59.9%) de 52 con elevación del lactato, 22(62.9%) de 35 pacientes con bajo índice cardiaco, 19(59.4%) de 32 con elevación de presiones derechas y en 21(77.8%) bajo cierre diferido del tórax. En 4 pacientes(1.6%)se detectaron hematomas mediastinales sin taponamiento que resolvieron con manejo conservador. Ocho pacientes(3.2%) bajo implante de dispositivos de asistencia ventricular presentaron eventos de succión manejados con el cambio de parámetros del dispositivo. En los 27 pacientes(10.7%) bajo cierre diferido del tórax determino el momento para el cierre definitivo.  No hubo complicaciones asociadas. Conclusiones: 1) Esta técnica modifico el diagnóstico inicial en pacientes inestables resultando la hipovolemia el principal hallazgo. 2) Pacientes con hematomas mediastinales pudieron manejarse en forma conservadora. 3) En pacientes bajo implante de dispositivos de asistencia ventricular permitió su manejo hemodinámico valorando disfunción derecha, eventos de succión y posición de la cánula de influjo. 4) En pacientes con cierre diferido del tórax determino el momento del cierre. 5) Mayor experiencia determinara el valor de esta técnica.

Background: Transesophageal echocardiography (TEE), a technique with almost universal applicability, is being used withincreasing frequency in the operating room, and the use of a miniaturized device for hemodynamic monitoring based on TEEis particularly useful in critically ill patients during the postoperative period.Objectives: The aim of this study was to evaluate the use of a miniaturized device for hemodynamic monitoring based on TEEanalyzing the number of patients evaluated, the hemodynamic findings and the associated complications.Methods: Unstable patients undergoing surgery were included between October 2010 and July 2012.Results: The device was used in 252/1,435 (17.6%) patients; hypovolemia was the main finding in 165 (73.4%) patients. Mediastinalhematoma was detected in 4 patients (1.6%) and resolved with conservative management. Eight patients (3.2%)under ventricular assist devices presented events. In the 27 patients (10.7%) undergoing delayed sternal closure, the devicehelped to determine the time to sternal closure. No associated complications were reported.Conclusions: This technique modified the initial diagnosis, and hypovolemia was the main finding. Patients with mediastinalhematoma could be managed with a conservative approach. The greatest benefit was achieved by patients under ventricularassist devices and by those undergoing delayed sternal closure. Further studies are necessary to determine the value of thistechnique.

Metadatos destacados

Colecciones
Argentine Journal of Cardiology

Editor

Sociedad Argentina de Cardiología

Fuente

Revista Argentina de Cardiología; Vol 83, No 5 (2015); 441-445, Argentine Journal of Cardiology; Vol 83, No 5 (2015); 441-445

Citación

Levin, Ricardo Luis; Vanderbilt University Medical Center et al., “Una imagen vale mas que mil numeros. Utilidad de un Novedoso Dispositivo para Monitoreo Hemodinamico basado en Ecocardiografia Transesofagica en Postoperatorio de Cirugia Cardiaca,” Archivo PPCT, consulta 1 de abril de 2026, http://archivoppct.caicyt.gov.ar/items/show/8278.

Dublin Core

Autor

Levin, Ricardo Luis; Vanderbilt University Medical Center
Degrange, Marcela Adriana; Universidad Abierta Interamericana
Porcile, Rafael
Salvagio, Flavio; Universidad Abierta Interamericana
Botbol, Alejandro Livio; Universidad abierta interamericana
Balaguer, jORGE Martin; Vanderbilt University
Byrne, John

Fuente

Revista Argentina de Cardiología; Vol 83, No 5 (2015); 441-445
Argentine Journal of Cardiology; Vol 83, No 5 (2015); 441-445

Editor

Sociedad Argentina de Cardiología

Fecha

2015-11-30

Colaborador

None

Derechos

Los que firman al pié, certificamos que tenemos total responsabilidad por la conducción de este estudio y por el diseño y la interpretación de los datos. Nosotros escribimos el manuscrito y somos responsables por la decisión acerca del mismo. Cada uno de nosotros cumple la definición de autor como se afirma en el Comité Internacional de Editores de Revistas Médicas (International Committee of Medical Journal Editors, ver www.icmje.org). Nosotros hemos visto y aprobado el manuscrito final. Ni el artículo, ni ninguna parte esencial del mismo, incluido las tablas y las figuras, será publicado o admitido para arbitrar a otra parte antes de aparecer en la Revista.También notificamos haber leído la sección “conflicto de intereses”, y revelaríamos cualquiera que existiera. Dejamos constancia que si nuestro artículo se publicara en la RAC, cederíamos los derechos (copyright) a la Revista.Los documentos publicados en esta revista están bajo la licencia Creative Commons Atribución-NoComercial-Compartir-Igual 2.5 Argentina.
Those signing below certify that we have full responsibility for the conduction of this study and for the design and interpretation of the information. We wrote the manuscript and are responsible for its decision. Each of us fulfills the definition of authorship as stated by the International Committee of Medical Journal Editors ( www.icmje.org). We have signed and approved the final manuscript. Neither the manuscript, nor any essential part thereof, including tables and figures, will be published or accepted for refereeing elsewhere before being published in the Journal. We have also read the "Conflict of Interest" section and would disclose any existing. We state that if our manuscript is published in the RAC, we shall transfer the copyright to the Journal.

Idioma

eng
spa

Tipo

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion