UTILIDAD DE LOS DISPOSITIVOS CARDÍACO ELECTRICOS CON MONITOREO A DISTANCIA EN PACIENTES PEDIATRICOS.;
Usefulness of Remote Monitoring of Pediatric Patients with Cardiac Implantable Electronic Devices

Creators:Maldonado, Sebastian; Hospital Nacional SAMIC J.P. Garrahan
Hospital Italiano de BS As
Hospital aleman de Bs As, Lafuente, Maria Victoria; Hospital Garrahan Cardiologa infantil, Benjamin, Monica; Electrofisologia infantil Hopital Garrahan, Gonzalez Puche, Edgardo; Fellow electrofisiología infantil Hospital Garrahan, Dome, Gisela; Cardiologa infantil Hospital Italiano de Bs As, Longarini, diego; Tecnico en cardiologia Hospital Garrahan, Guerchicoff, Marianna; Médica electrofisiologa infantil Hospital Italiano de Bs As, Garcia Delucis, Pablo; Jefe de cirugía cardiovascular del Hospital Garrahan, Sciegata, Alberto; Jefe de Electrofisiologia del Hospital Garrahan

Available Downloads

See details

Archivo Size
/journals/13/articles/11820/public/11820-45454575760806-1-PB.pdf
488.22 kB
/journals/13/articles/11820/public/11820-45454575760854-1-PB.pdf
800.21 kB
Descripción

Objetivo: Evaluar la utilidad de los dispositivos cardíacos eléctricos (DCEI) con sistema de monitoreo a distancia en una población pediátrica, y las limitaciones de su implementación en la República Argentina. Material y métodos: Se incluyeron 27 pacientes (p) a quienes se le implantó un DCEI con sistema de monitoreo a distancia en el Hospital Nacional Garrahan y en el Hospital Italiano de Bs As. Se evaluó la tasa de eventos, complicaciones y terapias por parte de los dispositivos. Se describieron las conductas anticipadas según la alerta recibida. Se realizó un seguimiento medio de 46,6 meses +/- 32,1. Resultados: La edad fue 12,2 años (RIC: 8,75-13,3),a 7 p (28%) se les implantó un cardiodesfibrilador implantable (CDI) y 20p (78%) un marcapaso endocavitario. 5 p (18,5%) presentaron 7 alertas rojas: 3 p  por arritmia ventricular en rango de fibrilación ventricular  y 4 p por alteraciones en alguno de los cables. 12 p (44%) presentaron una alerta amarilla: 6 p por alteraciones en los cables, 4 p por desactivación del sistema por falta de recepción de señal, 1 p por taquicardia ventricular (TV) y 1 p por taquicardia sinusal en rango de TV . En 9 p (33,3%) se tomó una conducta activa para resolver el aviso de alerta: en 2 p se realizó recambio de cable auricular en uno y ventricular en otro, en 2 p se detectó incumplimiento del tratamiento farmacológico y en la limitación del ejercicio, en el resto se reprogramó el dispositivo, según el tipo de alteración en el sensado y/o la captura. Conclusiones: El sistema de monitoreo remoto de DCEI es muy útil en la población pediátrica, lo que permite una rápida detección y acción cuando ocurre un fallo en el dispositivo o un evento arrítmico de relevancia clínica.

Objective: The aim of this study is to evaluate the usefulness of cardiac implantable electronic devices with remote monitoring system in a pediatric population and the limitations of its implementation in Argentina. Methods: Twenty-seven patients receiving a cardiac implantable electronic device with remote monitoring system at Hospital Nacional Garrahan and Hospital Italiano de Buenos Aires were included in the study. The rate of events, complications and device-related therapies were evaluated. The anticipated actions taken in response to alert notifications were described. Mean follow-up was 46.6 ± 32.1 months. Results: Median age was 12.2 years (IQR: 8.75-13.3). An implantable cardioverter defibrillator device was placed in 7 patients (25.9%) and 20 (74%) underwent pacemaker implant. Five patients (18.5%) presented seven red alerts: 3 due to ventricular arrhythmia in monitoring zone of ventricular fibrillation and 4 due to lead dysfunction. Twelve patients (44%) presented a yellow alert: 6 due to lead dysfunction, 4 due to deactivation of the monitoring system because of lack of signal reception, one due to ventricular tachycardia and another with sinus tachycardia in monitoring zone of ventricular tachycardia. Active actions were taken in 9 patients (33.3%) to manage the alert notification: the atrial lead was replaced in one patient and the ventricular in lead in another; in 2 patients non-compliance with pharmacological treatment and exercise limitation were detected and in the rest of the patients, the device was reprogrammed according to the abnormalities observed in the recording or capture. Conclusions: Remote monitoring of cardiac implantable electronic devices is very useful in the pediatric population, allowing for the rapid detection and management of device failure or significant arrhythmias.

Metadatos destacados

Colecciones
Argentine Journal of Cardiology

Editor

Sociedad Argentina de Cardiología

Fuente

Revista Argentina de Cardiología; Vol 86, No 1 (2018); 29-33, Argentine Journal of Cardiology; Vol 86, No 1 (2018); 29-33

Citación

Maldonado, Sebastian; Hospital Nacional SAMIC J.P. Garrahan Hospital Italiano de BS As Hospital aleman de Bs As et al., “UTILIDAD DE LOS DISPOSITIVOS CARDÍACO ELECTRICOS CON MONITOREO A DISTANCIA EN PACIENTES PEDIATRICOS.,” Archivo PPCT, consulta 2 de abril de 2026, http://archivoppct.caicyt.gov.ar/items/show/9397.

Dublin Core

Autor

Maldonado, Sebastian; Hospital Nacional SAMIC J.P. Garrahan
Hospital Italiano de BS As
Hospital aleman de Bs As
Lafuente, Maria Victoria; Hospital Garrahan Cardiologa infantil
Benjamin, Monica; Electrofisologia infantil Hopital Garrahan
Gonzalez Puche, Edgardo; Fellow electrofisiología infantil Hospital Garrahan
Dome, Gisela; Cardiologa infantil Hospital Italiano de Bs As
Longarini, diego; Tecnico en cardiologia Hospital Garrahan
Guerchicoff, Marianna; Médica electrofisiologa infantil Hospital Italiano de Bs As
Garcia Delucis, Pablo; Jefe de cirugía cardiovascular del Hospital Garrahan
Sciegata, Alberto; Jefe de Electrofisiologia del Hospital Garrahan

Fuente

Revista Argentina de Cardiología; Vol 86, No 1 (2018); 29-33
Argentine Journal of Cardiology; Vol 86, No 1 (2018); 29-33

Editor

Sociedad Argentina de Cardiología

Fecha

2018-05-31

Derechos

Los que firman al pié, certificamos que tenemos total responsabilidad por la conducción de este estudio y por el diseño y la interpretación de los datos. Nosotros escribimos el manuscrito y somos responsables por la decisión acerca del mismo. Cada uno de nosotros cumple la definición de autor como se afirma en el Comité Internacional de Editores de Revistas Médicas (International Committee of Medical Journal Editors, ver www.icmje.org). Nosotros hemos visto y aprobado el manuscrito final. Ni el artículo, ni ninguna parte esencial del mismo, incluido las tablas y las figuras, será publicado o admitido para arbitrar a otra parte antes de aparecer en la Revista.También notificamos haber leído la sección “conflicto de intereses”, y revelaríamos cualquiera que existiera. Dejamos constancia que si nuestro artículo se publicara en la RAC, cederíamos los derechos (copyright) a la Revista.Los documentos publicados en esta revista están bajo la licencia Creative Commons Atribución-NoComercial-Compartir-Igual 2.5 Argentina.
Those signing below certify that we have full responsibility for the conduction of this study and for the design and interpretation of the information. We wrote the manuscript and are responsible for its decision. Each of us fulfills the definition of authorship as stated by the International Committee of Medical Journal Editors ( www.icmje.org). We have signed and approved the final manuscript. Neither the manuscript, nor any essential part thereof, including tables and figures, will be published or accepted for refereeing elsewhere before being published in the Journal. We have also read the "Conflict of Interest" section and would disclose any existing. We state that if our manuscript is published in the RAC, we shall transfer the copyright to the Journal.

Idioma

eng
spa

Tipo

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion